A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff

A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff

Brand/Manufacturer: A&D MEDICAL
Hpfy stores Save
Authorized Retailer Badge
  • FSA Approved

A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff is easy to use and comes standard with just the right number of features. 15 memory recall provides ample storage for home use or while traveling. Systolic, diastolic and pulse rate are all shown simultaneously for easy review. Irregular Heartbeat Detection also comes standard. This key feature alerts the user to the presence of an irregular heartbeat while still providing an accurate reading.

Item # Desc Pkg Price
UA-651 3.8"W x 5.1"D x 2.7"H (97mm x 130mm x 69mm) Each
$71.49
$52.63

Features

  • A&D Medical LifeSource Basic Blood Pressure Monitor With SlimFit Medium Cuff features speed and accuracy at the touch of a single button
  • One of our most efficient devices
  • When using alkaline batteries a user can expect approximately 700 readings before having to change batteries
  • A battery life indicator appears on the screen preventing any surprises
  • SlimFit cuff, covering arm circumferences of 9" – 14.6" (23 – 37 cm) is easy to use and comfortable
  • Pressure Rating Indicator
    - Providing a snapshot of the users blood pressure classification according to the US JNC7 guidelines
  • Irregular Heartbeat Detection
    - Alerts the user to the presence of an irregular heartbeat while still providing an accurate reading
  • SimFit Cuff
    - A latex and metal free cuff design
  • Click Here For User Manual
  • Click Here For Instruction Manual

More Information

  • Instructions
    - To obtain an accurate reading, it is important to use the correct cuff size
    - A cuff that is too large will produce a reading that is lower than the correct blood pressure, a cuff that is too small will produce a reading that is higher than the correct blood pressure
  • Precautions
    - Precision components are used in the construction of this device
    - Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided
    - Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent
    - Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff
    - Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as such treatment may shorten the life of the components
    - The device and cuff are not water resistant
    - Prevent rain, sweat and water from soiling the device and cuff
    - Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, X-ray or other devices with strong electrical fields
    - When reusing the device, confirm that the device is clean
    - Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local regulations
    - Do not modify the device. It may cause accidents or damage to the device
    - To measure blood pressure, the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery. This may cause pain, numbness or a temporary red mark to the arm. This condition will appear especially when measurement is repeated successively
    - Any pain, numbness, or red marks will disappear with time
    - People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid medical problems
    - Do not self-diagnose the measurement results and start treatment by yourself
    - Always consult your doctor for evaluation of the results and treatment
    - Do not apply cuff on an arm with other medical equipment attached
    - Neither equipment may function properly
    - Do not apply the cuff on an arm with an unhealed wound
    - Do not apply the cuff on an arm receiving an intravenous drip or blood transfusion
    - It may cause injury or accidents
    - Do not use the device where flammable gases such as anesthetic gases are present. It may cause an explosion
    - Do not use the device in highly concentrated oxygen environments, such as a highpressure oxygen chamber or an oxygen tent
    - It may cause a fire or explosion
    - Do not excessively bend or squeeze the air hose
  • Maintenance
    - Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged
    - It is generally recommended to have the monitor inspected every 2 years to ensure proper functioning and accuracy

Specification

Particulars Specifications
Display 34.9 x 54.2mm (view area)
Memory Last 15 measurements
Pressurization Automatic, using micropump
Deflation Constant air release valve system
Type Oscillometric
Accuracy Pressure: ±3 mmHg. Pulse: ±5%
Power Source 4 x 1.5v batteries (R6P, LR6 or AA)
Recommended Operating Environment 50ºF to 104ºF (+10ºC to +40ºC). 800 to 1060hPa
Recommended Storage Environment -4ºF to 140ºF (-20ºC to +60ºC)
Classification Internally powered ME equipment (Supplied by batteries). Continuous operation mode
Weight 8.1 oz. (230g) without batteries
Pressure Range Pressure : 0 - 299 mmHg
Systolic pressure: 60 - 279 mmHg
Diastolic pressure: 40 - 200 mmHg
Pulse: 40 - 180 beats / minute
No. of Measurements Approx. 700 times LR6 (alkaline batteries)
Approx. 200 times R6P (manganese batteries)
With pressure value 180 mmHg, room temperature 23 °C

 

Warranty

  • Device: 5 years (when used six times a day)
  • Cuff: 2 years (when used six times a day)

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.damozelle.com

Close